RPCCurrentSource#

Class Arguments

Argument

Type

Default Value

rpc_currentsource

Component

min_current

TFloat

-inf

max_current

TFloat

inf

default_ramp_steps

TInt32

30

Bold arguments are mandatory. For more documentation on the listed arguments refer to the class definition below. If parameters appear in this list but not in the class definition below, please recursively check the linked base classes for the definition of the parameter.

Inheritance Diagram

Inheritance diagram of atomiq.components.electronics.currentsource.RPCCurrentSource

Example Component Dictionary

   {
    "currentsource_example": {
        "classname": "atomiq.components.electronics.currentsource.RPCCurrentSource",
        "arguments": {
            "rpc_currentsource": "<mandatory parameter (Component)>",
            "min_current": -1e999,
            "max_current": 1e999,
            "default_ramp_steps": 30
        }
    }
}

Class Description

class atomiq.components.electronics.currentsource.RPCCurrentSource(rpc_currentsource, *args, **kwargs)

Bases: CurrentSource

A current source controlled via RPC calls

Parameters:

rpc_currentsource (Component) -- The ARTIQ rpc object representing the current source. This object needs to provide a function named set_current(current_in_A) to set the current.

A Parametrizable is an entity that can be controlled by one or more continuous parameter(s)

ramp_current(duration, current_start, current_end, ramp_timestep=- 1.0, ramp_steps=- 1)

Ramp current over a given duration.

This method advances the timeline by duration

Parameters:
  • duration (TFloat) -- ramp duration [s]

  • current_start (TFloat) -- initial current [V]

  • current_end (TFloat) -- end current [V]

  • ramp_timestep (TFloat) --

  • ramp_steps (TInt32) --

set_current(current)

Set the current delivered by the current source

Parameters:

current (TFloat) -- Current in A