Eom exampleΒΆ

This example demonstrates the LineBroadeningEOM component. It is a resonant EOM that is used to broaden the linewidth of a laser by modulating sidebands onto it that are spaced by the linewidth of the optical transition.

The spacing argument sets the frequency spacing of the sidebands and is used as the center frequency of the EOM. Together with bandwidth (or an explicit freq_limit) it defines the RF range the EOM can be operated in. The broadening_calibration argument converts the requested broadening width (in Hz) into the RF amplitude that is sent to the EOM.

Experiment

from atomiq import AtomiqExperiment
from artiq.experiment import kernel, delay, ms


class EOMExample(AtomiqExperiment):
    """Atomiq Line-Broadening EOM Example

    This is an example experiment to demonstrate how to operate a line-broadening EOM. The EOM is driven by an RF
    source and broadens the line of a laser by modulating sidebands onto it that are spaced by the linewidth of the
    optical transition.
    """

    components = ["eom_broadening"]

    arguments = {
        "broadening_width": {"default": 5e6, "unit": "MHz"},
        "broadening_spacing": {"default": 5e3, "unit": "kHz"},
        "pulse_time": {"default": 1e-3, "unit": "ms", "scale": 1e-3, "precision": 2},
    }

    @kernel
    def step(self, point):
        # Add some slack
        delay(3 * ms)

        self.eom_broadening.on()

        # Set the width and comb spacing of the broadening.
        self.eom_broadening.set_broadening(
            width=point.broadening_width,
            spacing=self.eom_broadening.center_freq,
        )

        delay(point.pulse_time)

        # Ramp the broadening width down to zero over the pulse time. The spacing is left untouched.
        self.eom_broadening.ramp_broadening(
            point.pulse_time,
            width_end=0.0,
            ramp_steps=20,
        )

        # Switch the EOM off again
        self.eom_broadening.off()

Components

components = {"type": None}

# Calibration of the RF amplitude needed to achieve a given broadening width. The input
# is the width of the broadening in Hz, the output is the RF amplitude in [0..1].
components.update(
    {
        "cal_eom_broadening": {
            "classname": "atomiq.components.basics.calibration.LinearCalibration",
            "arguments": {"input_unit": "Hz", "output_unit": "amp", "a": 1e-8, "b": 0.0},
        }
    }
)

# RF source driving the EOM
components.update(
    {
        "dds_eom": {
            "classname": "atomiq.components.sinara.UrukulChannel",
            "arguments": {"urukul": "&urukul0", "device": "@urukul0_ch2", "ttl": "@ttl_urukul0_sw2"},
        }
    }
)

# The line-broadening EOM. It is a resonant EOM with a center frequency of 12 MHz and a
# bandwidth of 4 MHz, i.e. it accepts RF frequencies between 10 MHz and 14 MHz. The
# broadening calibration converts the requested broadening width into an RF amplitude.
components.update(
    {
        "eom_broadening": {
            "classname": "atomiq.components.optoelectronics.lightmodulator.LineBroadeningEOM",
            "arguments": {
                "rfsource": "&dds_eom",
                "switch": "&dds_eom",
                "spacing": 12e6,
                "bandwidth": 4e6,
                "switching_delay": 20e-9,
                "broadening_calibration": "&cal_eom_broadening",
            },
        }
    }
)